U.S. TOLL-FREE: 866.818.9729 > INTERNATIONAL: 330.425.4400

Portables



General Electric AMX IV/IV Plus– Collimator Assembly

P/N: 46-270615P1, T3438BF, 46-270615P2, T3497T

Challenges

      • Handle assembly will fail, button for field lamp fails, internal cables will fail.

Refurbishment Solutions:

      • Replacement of all Switches, Buttons, Face Plate, Overlay, Cables and Lamp.
      • Repainted to match OEM Specs.
      • Unit is shake tested to ensure all hardware is tested to its extremes to ensure no failures while in operation.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Drive Handle Assembly

P/N: 46-302276G1, 46-302276G2, 2280438, 2273437

Challenges:

      • Handle assembly will fail, Internal Switches will fail.

Refurbishment Solutions:

      • Replacement of all Switches.
      • Replacement of Handle.
      • Repainted to match OEM Specs.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Horizontal Arm

P/N: 46-302156G1, 2273438

Challenges:

      • Bearing will Fail, Brake assembly Fails, cable that controls break will fail.

Refurbishment Solutions:

      • Replacement of Failed Bearings, Brake Assembly, Cable.
      • Repainted to match OEM Specs.

SPECIAL NOTE: There is two styles of these units available, before ordering this part please measure the size of the block on the bottom of the arm and give that to your sales representative when ordering this product.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Front Caster

P/N: 46-303708P1

Challenges:

      • Needle Bearings Fail in wheel, Support Bearings Fail, Shock Springs Fail.

Refurbishment Solutions:

      • Replacement of Wheel includes new needle bearings, Support Bearings (if needed), New springs.
      • Repainted to match OEM Specs.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Cord Reel

P/N: 46-303474P1

Challenges:

      • Internal Retraction Spring Fails, Cord wears out.

Refurbishment Solutions:

      • Replacement of Retraction Spring (if needed), New Cord installed.
      • Unit tested to ensure good retraction of cord and proper installation of cord.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Vertical Column

P/N: 46-286991G3, 46-270158G1, T3497S

Challenges:

      • Bearings Fail, Wire Rope Supports Fail, Brake Fails, Bearing in Lower Assembly Fails.

Refurbishment Solutions:

      • Replacement of Bearings, Wire Support Ropes, Brake, Lower Bearing.
      • Repainted to match OEM Specs.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Lock Latch Assembly

P/N: 46-316308G1

Challenges:

      • Sensor Board Fails, Release Solenoid Fails, Spring Fails.

Refurbishment Solutions:

      • Replacement of Sensor Board (if needed), New style Solenoid installed, new spring.
      • Unit Tested for Twenty Four Hours on Machine.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Exposure Hand Switch

P/N: 46-270800G#

Challenges:

      • Internal Switches Fail, Housing will crack or is run over by portable.

Refurbishment Solutions:

      • Replacement of all Switches, all internal wiring, new housing (if needed)

PRICE INQUIRY



General Electric AMX IV/IV Plus– Display Board

P/N: 46-232832G1

Challenges:

      • Display has abnormal characters, prohibits adjustment of Kv or mAs.

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Drive Amplifier Board

P/N: 46-232836G2

Challenges:
Common Errors Seen when Board Fails:

      • 212-217
      • 212-213 (Left/Right Stall)
      • 214-217 (Current Feed Back)

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– 1KHz Drive Board

P/N: 46-288764G1

Challenges:
Common Errors Seen when Board Fails:

      • 439 & 469
      • Will not allow for calibration of kVp and Taps

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Rotor Control Board

P/N: 46-232786G2

Challenges:
Common Errors Seen when Board Fails:

      • 458, 320, 321
      • Will trip the circuit breaker upon Prep/Exposure and Collimator Lamp.

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– CPU Board

P/N: 46-264974G1, G2, G3, G4, G5, G6

Challenges:
Common Errors Seen when Board Fails:

      • 2, 3, 4, 43B, 454, 456, 45D, 463, 467
      • Trips Breaker upon Prep/Expose.
      • Will not allow for the calibration of the drive handle.
      • Will pull in taps upon starting the unit.

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Battery Charger Board

P/N: 46-288034G1, G2, G3, G4, G5, G6

Challenges:
Common Errors Seen when Board Fails:

      • 101-107
      • Will not allow battery charger calibration to pass. Will receive a battery charger error 1-4 on battery word unit.
      • Unit will not turn on.
      • Nothing happens when you plug it in for recharge.

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Drive Control Board

P/N: 46-232834G1

Challenges:
Common Errors Seen when Board Fails:

      • 210-211
      • Will not allow the unit to be driven

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Display Controller Board

P/N: 46-264982G1

Challenges:

      • When this board fails all displays will remain dark including the Display Board and the Display Controller

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY



General Electric AMX IV/IV Plus– Fil/kV Control Board

P/N: 46-264986G2

Challenges:
Common Errors Seen when Board Fails.

      • 462, 436, 454, 457, 462, 465
      • Will not calibrate mA and/or kVp.
      • Can only take low Kv exposures.

Refurbishment Solutions:

      • Replacement of all Component Level Items that have failed.
      • Unit is tested for forty eight hours.

PRICE INQUIRY